外文原文-基于變頻器的活塞式空氣壓縮機(jī)組控制系統(tǒng)設(shè)計(jì)
《外文原文-基于變頻器的活塞式空氣壓縮機(jī)組控制系統(tǒng)設(shè)計(jì)》由會員分享,可在線閱讀,更多相關(guān)《外文原文-基于變頻器的活塞式空氣壓縮機(jī)組控制系統(tǒng)設(shè)計(jì)(4頁珍藏版)》請?jiān)谘b配圖網(wǎng)上搜索。
Received: 2010-5-25Corresponding author: Yl WANG (wy@sdust.edu.crh附錄 2:外文原文Design of Piston Air Compressor Unit Control System basedConverterYi Wang, Hui-bin Liang, Mao-yong Cao, Di Fan{Shandong University of Science and Technology, Qingdao, 266510, China)E-mail: wy@sdust.edu.cnAbstract—Based on the running characteristics and high energy consumption of air compressors in coal mines, an air pressure PID closed loop control system has been designed in this paper. The system is composed of PLC, converter and sensors etc and adopts the control method of converter triple-evaporator which makes air supply Mneed-basedw. The designed system has been applied in multiple coal mines and the results show its energy saving is remarkable and potential application is widely.Keywords —— air compressor, converter, triple-evaporator, air pressure closed loop, energy savingManuscript Number: 1674-8042(2010)supp.-0050-03 dio: 10.3969/j .issn1674-8042.2010.supp 131 .IntroductionAccording to statistics, annual electricity consumption of the air compressors is about 10 percent of the total electricity consumption in coal mines [5J. Especially, with increasing of the coal production and consumption in recent years, electricity consumption of compressor which is one of the four most important equipments is more and more prominent. How to reduce the air compressor's energy consumption and saving energy have been the main targets in many coal mines [6\At present, the control systems of the mine-used piston air compressors (PAC) are mostly based on Y- A auto-induction voltage-reduced starter and relays simply. There were many disadvantages in these control systems such as large starting current, frequently loading and unloading, large fluctuation of air pressure, high rate of the mechanical fault and low automation, etc. This work mode will waste more electrical energy and shorten equipment’s life.Energy saving of air compressor is considered mainly from run and control mode, transmission modeand waste heat utilization, etc [7]. In this paper, an air pressure PID closed loop control system which includes PLC, converter and sensors etc was designed to change the original run and control mode. The control method of converter triple-evaporator has been adopted and it can realize the dynamic regulation and “need-based ” air supply. Then the load rates of the compressors can be balanced because of the using of “first starting then first stopping”. Compared with intake throttling control, the application of the converter control in compressors unit will save energy about 30%~50%[8J.The designed converter control in the compressors unit has been applied in multiple coal mines such as XinYi mine. The energy saving is significant and application is wide. With the development of frequency conversion technology and the upsurge of energy saving requests, the technology that the speed control and energy saving are realized by the converter in the compressors unit will be extended widely in coal mines and other industries.2. Conversion Control System of Piston Air Compressors Unit^Converter Triple-evaporator AirCompressors Control SystemIn order to realize the “need-based” air supply,that is the air supply amount is adjusted automatically by the system according to the needs of air under coal mine and the stable air pressure in pipe network will be kept, the converter control technology has been adopted.As for three piston air compressors unit (PACU), the basic frame of the converter control system is shown in Fig.l. The main compositions of the system are a touch screen, a set of converter, a set of S7200 PLC (including the EM231 module), EM277 communication module, industry PROFIBUS field bus, CB communication boards, motor electronic protector and sensors of current, voltage, pressure and temperature.Fig.l The basic frame of the converter control PACUsystemTab. 1 Set Value to the Parameters of ConverterparameterSetvalue parameterSetvalueP0304 380 PI 080 30P0305 255 R2050fll P2253P0307 132 R2050[21 P2264P0308 0.78 P2200 1P0640 120 P2280 0.4P0700 6 P2285 10P1000 6 P2051 21In coal mines, the supply air pressure can not vary greatly within a short time and the PAC must be driven one by one. So it is reasonable and feasible to adopt the control method of converter triple-evaporator in PACU. Here the converter, which capacity is the same as that a PAC, sequentially drives the three piston air compressors. Thus not only the system energy consumption can be much saved but also the cost of system can be decreased.2.2 Selecting and Parameter Setting of ConverterConsidering the load characteristic, speed range, starting torque, application environment of the PAC, we have adopted the siemens 380V132KW converter of MM440 series to realize speed control with constant torque in the system. The converter is of faster self-starting, starting torque bigger and stronger overload capacity.In order to realize the good control performance of the system, we must set concrete numerical value to the converter inherent parameters and BICO. Table I has listed main parameter setting of converter3. The work process of the system3.1 The Control Process of the SystemWhen the system working, the pressure transmitter converts the air pressure signal of main pipe into electrical signal and sends it to PLC, the air pressure setting value and pressure detection value are send to converter by PLC through PROFIB US industrial bus and CB communication board, the motor speed is controlled by the internal PID of converter, then the air supply amount is regulated, and the actual air pressure value is adjusted to the setting pressure value. Furthermore the close loop control of air pressure has been realized. When the operating frequency of converter has reached 50HZ, if the actual air pressure value can not reach the setting value, then the compressor which is driven by converter will work with industry frequency automatically, at the same time another compressor was drove by converter to supplement air. PLC regulates the number of compressors unit and realizes IF-FF switching by measuring the air pressure of main pipe and monitoring the converter status. In addition, the system can also monitor the important online parameters, such as temperature, pressure, electric quantity etc, if these parameters are abnormal, it can alarm after a while. Fig. 2 is the control process of the compressor system.3.2 “First Starting then Fist Stopping” SequenceFig.3 shows the start-stop sequence of the compressors which is called ltfirst starting then fist stopping^. When the 1# compressor has been started by converter, it is loaded and made the PID regulation after the frequency reaches 30HZ. If the outlet air pressure of main pipe has not reached the presupposition-pressure after the frequency value of converter reaches 50HZ, the PLC will stop the converter and do the make-break of relays, in the meantime the 1# compressor which has been driven by converter will work with industry frequency automatically, and 2# compressor is driven by converter to supplement air. 3# follows 2# compressor with the analogous switch steps, and the last operating compressor will be driven by converter. If the frequency value decreases to 30HZ after the using air pressure reduces, then the PLC will stop the compressor which has the longest running time and works with industry frequency. During the system working, the malfunction machine will be stopped and cut out of automatic control cycle by PLC when the fault or stopping signals occurs. The malfunction machine can just enter the automatic cycle only after debugging and fault resetFig.2 The control process of the compressor systemFigJ The control sequence of wfirst starting then fist stopping,,Tab.2 The Comparison of the Parameter in the PrimaryControl System and New Designed System.parameters The parameters ranges of the primary systemTheparameters ranges of the new systemUS ECurrent 100A,210A 100A?210AVoltage 0V,380V 230V ?380VPower 105KW,132KW 78KW ?132K Wo Supplyair 0 m3,22m3 12 m3?22 m 3TheaircompressorsCurrent100A,210A,310A,420A,520A,630A100A ?210A 310A-420A 520A?630APower105KW,132KW,237KW,264KW,369KW,396KW78KW ?132K W210KW-264KW342KW-396KWSupplyair22 m3,44 m3,66 m3(A1=0,A2=A3,A4=A5)12 m3?22 m3 34 m3?44 m3 56 m3?66 m 34. The Change of Operation Parameters in SystemThere are four key operation parameters of compressor which are voltage, current, power and air supply amount. Their ranges were six discrete points (Expressed as Al, A2, A3, A4, A5 and A6) because the system is controlled by relays simply. It is shown in the Fig. 4.When the converter is adopted to control the compressors, the ranges of operation parameters changes into continuous lines from some discrete points, which are shown in Fig. 5. Because the parameters ranges are dynamically continuously adjustable, the air supply of the whole system becomes flexible, the starting current is decreased, the cost and energy are saved, the reliability and automation level of the system are improved.The comparison of the parameters in the primary control system i table II.Fig.4 The adjustable ranges of the parameters inrelays system5. Energy Saving Analysis of the Converter Control SystemThe running cost of the PACU is mainly of electricity, oil and mechanical wear etc. After using the conversion control system, the system is realized electricity saving, oil saving, low fault rate and small mechanical wear. The saving L u.1 o.! —\ _ iI iB-? i sa_LA6A5A4A3A2A1的SJ9J9UIBJBCLFig.5 The adjustable ranges of the parameters in new systemA6A5A4A3A2A1of the electricity and oil has been analyzed as follows:i. Annual electric quantity savingHere a mine with three 132KW PAC takes as a example. If the PACs woric on rated speed for 12 hours and work on 60%?70% rated speed for another 12 hours every day, and electricity saving rate is 50%,then the annual electric quantity saving is3x12x132x0.5x365 = 867240 (KW) .⑴ii. Annual oil savingAccording to the using oil rule of “l(fā)ow speed then low lubrication,’,the converter control system can save oil 60%.6. ConclusionsAs for the problem of high energy consumption in compressors, we have designed the converter triple-evaporator air compressors control system. Compared with the original relays control system, the starting current and equipment wear of the new system are much reduced, besides the system is low operation cost and high automation. This system has been used in some mines such as XinYi and the energy saving is remarkable, the control technology and system can be used or referenced in other mines and corporations.References[1] Miller,Harry (Dresser-Rand) and etc.: “Totally Enclosed Inline Electric Motor Drive Gas Compressors’’, 2002. 1.[2] MAN TURBO CO. f^MOPICO TURBO wins order for three MPOPICO compressors for natural gas transmission service”, 2004.[3] YANG Guo-fu wPresent Situation of Frequency Converter & the Trend of Frequency Conversion Technology Developmentw Jiangsu Electrical Apparatus,2007.[4] LU Xin-nan “Control Strategy Analysis on Frequency Conversion Renovation of Air Compressor** Zhe Jiang Electric Power,2008.[5] Zhao Xue-hua,HU Yong-jun,Chen Li-bing MBased on PLC The Frequency Control System of compressor in coal mine1* Safety in Coal Mines,2009.4 .[6] LI Wen - hua^ZHANG Zong - zhen “Energy Consumption and Eneigy - saving Tendency of MineAir Compressors** Coal Mine Machinery, 2006.8.[7] Wang Shu-fen^ Frequency Conversion Modification of Air2jet Loom by Using A ir Compressor” Cotton Textile Technology,2009.3.[8] GAO Xiang2jia, CHEN Fang ^Economic Analysis and Techn ica 1 Program of Energy Conservation for Conversion Frequency Screw A ir Compressor” Compressor Technology,2009.3.- 1.請仔細(xì)閱讀文檔,確保文檔完整性,對于不預(yù)覽、不比對內(nèi)容而直接下載帶來的問題本站不予受理。
- 2.下載的文檔,不會出現(xiàn)我們的網(wǎng)址水印。
- 3、該文檔所得收入(下載+內(nèi)容+預(yù)覽)歸上傳者、原創(chuàng)作者;如果您是本文檔原作者,請點(diǎn)此認(rèn)領(lǐng)!既往收益都?xì)w您。
下載文檔到電腦,查找使用更方便
10 積分
下載 |
- 配套講稿:
如PPT文件的首頁顯示word圖標(biāo),表示該P(yáng)PT已包含配套word講稿。雙擊word圖標(biāo)可打開word文檔。
- 特殊限制:
部分文檔作品中含有的國旗、國徽等圖片,僅作為作品整體效果示例展示,禁止商用。設(shè)計(jì)者僅對作品中獨(dú)創(chuàng)性部分享有著作權(quán)。
- 關(guān) 鍵 詞:
- 外文 原文 基于 變頻器 活塞 空氣 壓縮 機(jī)組 控制系統(tǒng) 設(shè)計(jì)
鏈接地址:http://www.820124.com/p-587632.html